<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>qEEGsupport.com &#187; qeeg amplifier</title>
	<atom:link href="http://qeegsupport.com/tag/qeeg-amplifier/feed/" rel="self" type="application/rss+xml" />
	<link>http://qeegsupport.com</link>
	<description>Quantitative Electroencephalography (qEEG): Information &#38; Discussion</description>
	<lastBuildDate>Fri, 30 Mar 2012 21:31:55 +0000</lastBuildDate>
	<generator>http://wordpress.org/?v=2.8.4</generator>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<xhtml:meta xmlns:xhtml="http://www.w3.org/1999/xhtml" name="robots" content="noindex" />
		<item>
		<title>Concern Regarding the Mitsar Amplifier</title>
		<link>http://qeegsupport.com/concern-regarding-the-mitsar-amplifier/</link>
		<comments>http://qeegsupport.com/concern-regarding-the-mitsar-amplifier/#comments</comments>
		<pubDate>Sat, 19 Dec 2009 22:41:00 +0000</pubDate>
		<dc:creator>Jay Gunkelman</dc:creator>
				<category><![CDATA[neurofeedback]]></category>
		<category><![CDATA[qEEG]]></category>
		<category><![CDATA[brain mapping]]></category>
		<category><![CDATA[mitsar]]></category>
		<category><![CDATA[qeeg amplifier]]></category>
		<category><![CDATA[qeeg database]]></category>

		<guid isPermaLink="false">http://qeegsupport.com/?p=420</guid>
		<description><![CDATA[The concern regarding the Mitsar amplifier expressed  with so much vigor by those with competing interests has met the reality test  of actual recorded data.  The concern expressed was over a theoretical time  skewing error due to the data sampling of an older version of the Mitsar  amplifier.
I suggested at the [...]]]></description>
			<content:encoded><![CDATA[<p>The concern regarding the Mitsar amplifier expressed  with so much vigor by those with competing interests has met the reality test  of actual recorded data.  The concern expressed was over a theoretical time  skewing error due to the data sampling of an older version of the Mitsar  amplifier.</p>
<p>I suggested at the time that all the emotion was merely an  example of someone yelling &#8220;the sky is falling&#8221;, like Chicken Little. There  was no real problem, just lots of crying out and hand wringing.</p>
<p>I  requested in an open international forum for anyone to send me a sample  of the problem, and none could be produced. I suspected there was no real problem, as the sample issue was concerning a 500 sample/second device having a time skew&#8230; though this was in comparison to a database  collected on a 100 sample per second device, with the waveforms interpolated  from these samples.<span id="more-420"></span></p>
<p>It was highly suspect from my technical  perspective when this issue was raised, and it was even more suspect when  nobody could produce actual data showing the coherence or phase  issue.</p>
<p>Testing now has shown that the old style Mitsar, with the  non-simultaneous sampling is identical in performance to the new style  amplifier that has simultaneous sampling, and thus no skewing error is  possible in the newest amp.  There is also an intermediate style amplifier  tested, which is one of the smaller amps, but with a more current sampling  design.</p>
<p>The data clearly show that there is no difference in coherence  between these devices.</p>
<p>The Mitsar amplifier also has been tested with  the new BranMaster  Discovery amplifier, and it also was shown to have  indenticle coherence findings with the Mitsar amplifier.</p>
<p>Clearly there  is no real issue.</p>
<p>Data rules&#8230;. the experimental details are  below.</p>
<p>Jay</p>
<p>We performed the following  experiment.</p>
<p>We took three different Mitsar amplifiers:</p>
<p>1.  Mitsar-EEG-201 &#8211; old model of amplifiers with relatively large time  shift between channels (1.75 ms maximum) 2. Mitsar-EEG-201M &#8211; new model  of amplifiers with relatively small time shift between channels  (470 microsecond maximum) 3. Mitsar-EEG-202 &#8211; 32-channels amplifiers with zero time shift between channels.</p>
<p>Than we take Electro-Cap and put it  on the head of one subject. We used linked ears referent for EEG  recording.</p>
<p>We sequentially connect Electro-Cap and referents to three  different amplifiers and perform independent recording of EEG in eyes  closed condition. The duration of recording was longer than 300  seconds.</p>
<p>When we reconnect Electro-Cap and referents from one amplifier  to another we do not touch to electrodes on the head and ears.</p>
<p>The  total time of out experiment was approximately 20 minutes. This means the  functional state of subject remain relatively stable.</p>
<p>Than we remontage  the EEG to average referent (very important for time  shift influence  measurements), compute the coherence for all three EEG recordings using the  same processing parameters and compare them. The duration of time interval  for processing was the same for these EEG recording and was equal to 300  seconds.</p>
<p>We do not find any dramatic differences in coherence  corresponding to different amplifiers. The small fluctuations can be explaned  by amplifiers noise and non-stationarity of EEG.</p>
<p><span style="font-family: Arial; font-size: x-small;"><img class="aligncenter" title="Mitsar Comparison Results" src="http://qeegsupport.com/wp-content/uploads/2009/04/comperisonresults.jpg" alt="comperisonresults Concern Regarding the Mitsar Amplifier" width="711" height="1575" /><br />
</span></p>
<p><strong>Mitsar Calibration</strong></p>
<p>The Mitsar system is calibrated at the manufacturer. There is no need to recalibrate the amplifier unless there is a serious problem from damage. The calibration button is so the user can run a test calibration signal to demonstrate that the channels are in fact correct and equal. If these were ever not correct (or equal) then the manufacturer would recalibrate the hardware device. It is blocked so that a user cannot accidentally mess the calibrations up.  So in summary the  calibration button in the software is pressed and then the button to observe EEG is pressed. Then the test calibration signal is generated and can be recorded. This is a good idea if the case is a medical or legal evaluation so that when the data is presented as evidence there is validation that a microvolt equals a microvolt.</p>
<p><a class="a2a_dd addtoany_share_save" href="http://www.addtoany.com/share_save#url=http%3A%2F%2Fqeegsupport.com%2Fconcern-regarding-the-mitsar-amplifier%2F&amp;title=Concern%20Regarding%20the%20Mitsar%20Amplifier"><img src="http://qeegsupport.com/wp-content/plugins/add-to-any/share_save_171_16.png" width="171" height="16" alt="share save 171 16 Concern Regarding the Mitsar Amplifier"  title="Concern Regarding the Mitsar Amplifier" /></a> </p>]]></content:encoded>